Monarch-instrument DC 2000 Bedienungsanleitung

Stöbern Sie online oder laden Sie Bedienungsanleitung nach Ausrüstung Monarch-instrument DC 2000 herunter. Monarch Instrument DC 2000 User Manual Benutzerhandbuch

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 160
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 0
Data-Chart Data-Chart
Data-Chart Data-Chart
Data-Chart
®
2000 2000
2000 2000
2000
Paperless Recorder
MONARCH INSTRUMENT
Instruction Manual
15 Columbia Drive
Amherst, NH 03031-2334 USA
Phone: (603) 883-3390
Fax: (603) 886-3300
Website: www.monarchinstrument.com
IMPORTANT!
Please format all floppy disks in
the Recorder prior to use.
Because floppy disks are volatile,
do not use disks for more than
2-3 months. Also, use a floppy
cleaning disk every 4 months to
clean the heads.
Seitenansicht 0
1 2 3 4 5 6 ... 159 160

Inhaltsverzeichnis

Seite 1 - Paperless Recorder

Data-Chart Data-Chart Data-Chart Data-Chart Data-Chart ® 2000 2000 2000 2000 2000Paperless RecorderMONARCH INSTRUMENT Instruction Manual15 Columbia

Seite 2

Page 1-2Chapter 1 General Description1.1 Recorder DescriptionThe Solid State Data Recorder is a Paperless Recording instrument. Data is stored on ei

Seite 3 - Overview

Page 5-34Chapter 5 ProgrammingTo set record rates use the UP (↑) or DOWN (↓) Arrow Keys to highlight “Record Rate” on the menu and pressENTER. There

Seite 4

Page 5-35Chapter 5 Programming5.7.7 Disk Full AlarmIt is possible to set a threshold to indicate when the disk is full. The indication is via a pop-

Seite 5

Page 5-36Chapter 5 Programming5.7.9 Save ConFiGuration FileThis function permits the saving of the unit configuration to the disk for later retrieval

Seite 6

Page 5-37Chapter 5 ProgrammingTo enter a filename use the UP (↑) or DOWN (↓) Arrow Keys to highlight “Filename” and press ENTER. You willbe presented

Seite 7 - Chapter 1 General Description

Page 5-38Chapter 5 Programming5.9 DIGITAL I/OThe Digital I/O (Relay Outputs, Optocoupled inputs) option must be fitted in order for the following to

Seite 8

Page 5-39Chapter 5 Programming5.9.1.4 Selecting and Programming ReflashUse the UP (↑) or DOWN (↓) Arrow Keys to highlight “Reflash” and press ENTER.

Seite 9

Page 5-40Chapter 5 Programming5.9.2.4 Alarm AcknowledgeThe external event can be used as an Alarm Acknowledge. This has the same effect as pushing t

Seite 10 - 1.1 Recorder Description

Page 5-41Chapter 5 Programming5.10 COM PORTSThe Com Ports Menu selection, in the Program Menu, allows the user to select and set up the communicatio

Seite 11 - 1.1.6 Recorder Construction

Page 5-42Chapter 5 ProgrammingTo set up Demand Data, use the UP (↑) or DOWN (↓) Arrow Keys to highlight “Demand data” and pressENTER to get the follo

Seite 12 - 1.3 Recorder Options

Page 5-43Chapter 5 Programming5.10.1.5 EthernetThis option allows the user to configure the unit for Ethernet connection. To set up the Ethernet opt

Seite 13 - 1.4 Specifications

Chapter 1 General DescriptionPage 1-31.1.3.1 Display MenuThe Display Menu is accessed by pressing the Display button (DISPL) on the Command Button B

Seite 14 - Page 1-6

Page 5-44Chapter 5 Programming5.10.3 Modem SetupThis menu option allows the user to enable and set up a modem string for a modem connected to the R

Seite 15

Page 5-45Chapter 5 ProgrammingRefer to the modem manual for other modems. The modem needs to be set up as follows.Operation Rockwell etc. U

Seite 16

Page 5-46Chapter 5 ProgrammingUse the UP (↑) or DOWN (↓) Arrow Keys to select which passcode you want to enter and press the ENTERbutton. The display

Seite 17 - Chapter 2 Installation/Wiring

Page 5-47Chapter 5 Programming5.11.4 Printer OutThis option allows the user to configure the Parallel Printer Port to print point data and/or events

Seite 18

Page 5-48Chapter 5 ProgrammingFor example, with the options stated below, you would get a printout similar to the following:Data print data=YESEvents

Seite 19 - CHAPTER 2

SAFETY NOTICE This Safety Notice has been included to emphasize the DANGER OF HAZARDOUS VOLTAGES on the REAR TERMINAL PANEL of your instrument. USE

Seite 21 - Front Panel

Chapter 6 Calibration6.1 Introduction ...

Seite 23 - 2.3.2 Power Connections

Chapter 6 CalibrationPage 6-16.1 IntroductionThis chapter includes the procedures to calibrate the Analog-to-Digital Converter (ADC) circuit board a

Seite 24 - 2.3.3 Signal Input Wiring

Page 1-4Chapter 1 General Description1.2 Recording OptionsThe Recorder can be ordered with one of three storage mediums: a standard PC compatible fl

Seite 25

Chapter 6 CalibrationPage 6-26.3 Scale CalibrationThe Recorder menu supports full calibration for the voltage and current input ranges of the instru

Seite 26 - WARNING

Chapter 6 CalibrationPage 6-3Figure 6-1CalibrationResistorConnection6.4 RTD Current CalibrationThe ADC current source is used for RTD measurements a

Seite 28 - 2.6 Cleaning

Chapter 7 Get Data Software7.1 Overview ...

Seite 30

Chapter 7 Get Data SoftwarePage 7-17.1 OverviewThe Get Data Software is a 16 bit software package that runs under the Microsoft Windows 3.1, Windows

Seite 31 - 4/17/01 15:52:35

Chapter 7 Get Data SoftwarePage 7-27.3.1.2 Export Dialog Box7.3.1.2.1 Start Date and TimeSelect the time to start exporting data, thus allowing par

Seite 32

Chapter 7 Get Data SoftwarePage 7-3The thumb button shows where the visible part of the object is relative to the beginning and end.Every time the ob

Seite 35

Chapter 1 General DescriptionPage 1-51.4 SpecificationsOPERATINGInput Signals DC Voltage: Linear, Industrial square root, LogarithmicFull scale ran

Seite 36

→ → → → ←←←←6. 9. 8. 7. 5.

Seite 37

11. 12. 13. 14. 10.

Seite 39 - 3.3.5 File Browsing

→ → → → →→→→21. 22. 23. 24. 20.

Seite 40

26. →→→→25.

Seite 43 - 3.7 Programming Time and Date

→→→→ ←←←←→ → → → ←←←←→ → → → ←←←←11. 12. 13. 14. 10.

Seite 44 - 3.8 Programming Points

→→→→ ←←←←16. 17. 18. 19. 15.

Seite 46 - 3.10 Recording Data

Page 1-6Chapter 1 General DescriptionDISPLAYDisplay Type Mono CCFL backlit STN Liquid Crystal Display (5.0 inch) with touchscreen control.Resolution

Seite 47

→ → → → ←←←←26. → → → → ←←←←27→ → → → ←←←←282925.

Seite 48

30Attach cable shield to chassis ground. Place 50 ohm resistor across input + and –. Link – and C terminals.

Seite 50

1. 4. 3. 2.

Seite 52

11. 12. 13. 14. 10.

Seite 53 - 4.1 Instrument Power-up

→ → → → ←←←←→ → → → ←←←←→ → → → ←←←←16. 17. 18. 19. 15.

Seite 57

SAFETY NOTICE This Safety Notice has been included to emphasize the danger of hazardous voltages on the REAR TERMINAL PANEL of your instrument. USE

Seite 59

11. 12. 13. 14. 10.

Seite 60 - 4.2.4 Hidden Menu

→→→→ ←←←←16. 17. 18. 19. 15.

Seite 61

→→→→ ←←←←21. 23. 22. 24. 20.

Seite 63 - Chapter 5 Programming

DATA-CHART® LIMITED WARRANTY STATEMENT MONARCH INTERNATIONAL, INC. (SELLER) SELLER warrants new hardware products to be free from any defect in mat

Seite 65

RETURN AUTHORIZATION All equipment and/or parts to be returned to Monarch Instrument, for repair or credit, must have a Monarch Return Merchandise

Seite 66

PACKING INSTRUCTIONS Instruments that are to be returned to the factory for repairs or credit must be packed according to the following instruction

Seite 69 - Display Menu

1071-4882-116Printed in the U.S.A.© Monarch Instrument 2002 all rights reserved

Seite 70 - 5.4.3 Power Up Display

Chapter 2 Installation/Wiring2.1 Equipment Handling ...

Seite 72 - 5.5 Charts/Pens

Page 2-1Chapter 2 Installation and WiringCHAPTER 2This chapter provides information and procedures on installing and wiring the Recorder. Included a

Seite 74 - 5.5.3 Pens

Page 2-2Chapter 2 Installation and Wiring2.2 InstallationThe instrument is intended to operate in the following environment:Indoor Use OnlyInstallati

Seite 75 - 5.6 Points

Page 2-3Chapter 2 Installation and Wiring2.2.1 Panel MountingThe Recorder should be mounted in a vertical panel to ensure proper operation. Ensure yo

Seite 76 - 5.6.2 Programming Points

Page 2-4Chapter 2 Installation and Wiring2.2.1.5 With the Recorder held firmly in place against the panel, install one of the locking bar assemblies

Seite 77 - 5.6.3 Point Options

Page 2-5Chapter 2 Installation and Wiring2.3 Wiring Specifications and Procedures2.3.1 Power RequirementsThe Recorder operates on any voltage from

Seite 78 - 5.6.5 Programming Parameters

Page 2-6Chapter 2 Installation and WiringThis unit is equipped with an AC mains fuse internally. If this fuse should blow, it generally indicates a

Seite 79

Page 2-7Chapter 2 Installation and WiringThe Recorder accepts up to six direct inputs. Input connection is via plug in screw terminal connectors on

Seite 80

Page 2-8Chapter 2 Installation and Wiring2.3.4 Relay Output, Contact Input WARNINGTo prevent the possibiltiy of electrical shock, use extreme cauti

Seite 81

Page 2-9Chapter 2 Installation and Wiring2.4 Serial Interface OptionData can be accessed to download Configuration files or Data files using the RS23

Seite 82

Page 2-10Chapter 2 Installation and Wiring2.5 Ethernet OptionThe 10BaseT Ethernet option allows direct connection to a LAN or WAN and the standard TC

Seite 83

Chapter 3 Getting Started3.1 Moving About the Screen ...

Seite 84

Data-Chart Data-Chart Data-Chart Data-Chart Data-Chart ® 2000 2000 2000 2000 2000OverviewMONARCH INSTRUMENT Instruction ManualChapter 1 ...

Seite 85

3.10.3 Programming the unit for recording ... 3-183.10.3.1

Seite 86

Chapter 3 Getting StartedPage 3-1The Instrument is an extremely versatile solid state data recorder. It has a liquid crystal display capable of comp

Seite 87

Page 3-2Chapter 3 Getting StartedThe VIEW button is on the lower left side of the screen, and it enables the user to scroll through the selectabledis

Seite 88

Chapter 3 Getting StartedPage 3-33.2 What the Screens MeanThe basic screen layout is shown in Figure 3-3 below. Each area is used to present differen

Seite 89

Page 3-4Chapter 3 Getting Started3.2.3 Button BarThe Button Bar is the area across the bottom of the screen where the main menu buttons appear. The f

Seite 90 - 5.6.7 Dry Contact Point Type

Chapter 3 Getting StartedPage 3-53.2.5.2 Digital WindowsDigital Windows can be displayed on their own or as part ofa split screen. Up to twelve can b

Seite 91

Page 3-6Chapter 3 Getting Started3.2.5.4 Trend WindowThe trend window is the one that looks like a “paper” recorder. It has traces or pens and emulat

Seite 92 - Section 5.6.5.8

Chapter 3 Getting StartedPage 3-73.2.5.5 Transient WindowsTransient windows are those that appear momentarily. They popup over any existing window to

Seite 93

Page 3-8Chapter 3 Getting Started3.3.2 Searching Data By TimeThe historic data can be searched by time, by pressing the FINDT (FIND Time) button. Thi

Seite 94

Chapter 3 Getting StartedPage 3-93.3.4 Interactive BrowseThe interactive browse mode enables the user to uniquely identify points on the screen by ti

Seite 96

Page 3-10Chapter 3 Getting Started File DirectoryPoint: 1 BATCH1 .DT1< BATCH2 .DT1 BATCH3 .DT1If only one file is available per point, th

Seite 97 - 5.7 Record Setup

Chapter 3 Getting StartedPage 3-113.4 Getting to the PointsThe Instrument is a 15 point recorder of which up to 6 channels may be direct or real worl

Seite 98 - 5.7.3 Record Mode

Page 3-12Chapter 3 Getting StartedThe input to any channel in the conditioning block can be any one of the base points, or it can be the live inputs.

Seite 99 - 5.7.5 Points (Trigger)

Chapter 3 Getting StartedPage 3-13It is then necessary to define chart scale A to suit the requirement - Section 5.5.2. In order to maximize thedisp

Seite 100

Page 3-14Chapter 3 Getting Started3.8 Programming PointsThe points are the input or calculated channels that are assigned to the display or are recor

Seite 101 - 5.7.8 Format Disk

Chapter 3 Getting StartedPage 3-153.8.3 Output ScaleThe output scale is the value that will be reflected on the display or recorded to the units and

Seite 102

Page 3-16Chapter 3 Getting Started3.9.1.1 Scale EndsUse the arrow keys to select Scale Ends and press ENTER. You are presented with a menu to selec

Seite 103 - 5.8 MEASUREMENT

Chapter 3 Getting StartedPage 3-174,000 samples. Alarm/Event log files record all alarm and/or events to disk. Each alarm or event uses the spaceof

Seite 104 - 5.9 DIGITAL I/O

Page 3-18Chapter 3 Getting Started3.10.3 Programming the unit for recordingTo program the unit for recording, press MENU in the bottom right corner

Seite 105 - 5.9.2 Switches In

Chapter 3 Getting StartedPage 3-19To stop the recording return to the same menu and select “Record Off”. From the pop-up window showing“record off?”

Seite 106 - 5.9.3 Event Messages

SAFETY NOTICE This Safety Notice has been included to emphasize the DANGER OF HAZARDOUS VOLTAGES on the REAR TERMINAL PANEL of your instrument. USE

Seite 107 - 5.10 COM PORTS

Page 3-20Chapter 3 Getting Started3.14 Loading and Saving Configuration FilesOnce all the points have been set up and all other data has been progra

Seite 108

Chapter 4 Operation4.1 Instrument Power-up ...

Seite 110 - 5.10.3 Modem Setup

Chapter 4 OperationPage 4-14.1 Instrument Power-upThe Recorder executes multiple tests at initial start-up. These tests are referred to as Start-up

Seite 111 - 5.11 SYSTEM

Chapter 4 OperationPage 4-2If the Recorder finds a bad checksum in any Point DPR during the power-up load sequence, it will not issue anyerror messag

Seite 112 - 5.11.3 Alternate Language

Chapter 4 OperationPage 4-3Bargraph/Pens BlockPen Assignments = Set to Pen 1 = point 1, Pen 2 = point 2, Pen 3 = point 3,Pen 4 = point 4, Pen 5 = poi

Seite 113 - 5.11.4 Printer Out

Chapter 4 OperationPage 4-44.2 MenusProgramming procedures available through the Command Menu Button Bar are initiated by pressing the MENUbutton at

Seite 114

Chapter 4 OperationPage 4-5NOTE: To have the point information come up automatically at power up and be the default display, usethe Display Programmi

Seite 115 - WARNING

Chapter 4 OperationPage 4-64.2.2 PROG (Program) MenuThe Program Menu allows the user to program inputs and associated parameters into the Recorder.

Seite 116

Chapter 4 OperationPage 4-74.2.3.1.3 TriggerSelecting Trigger will enable the unit to record from an external event or internal alarm. Internal reco

Seite 118

Chapter 4 OperationPage 4-8To select the chart speed, press the FUNCTION Key at the “COMMAND” prompt and use the UP (↑) orDOWN (↓) Arrow Keys to high

Seite 119 - 6.2 Zero Calibration

Chapter 4 OperationPage 4-94.2.4.1 InitializeCAUTION: USE OF THESE MENU ITEMS WILL ADVERSELY AFFECT THE SYSTEM CONFIGURATION. REFERTO SECTION 4.1.3

Seite 121 - 6.5 Calibration Recall

Chapter 5 Programming5.1 Introduction ...

Seite 122

5.6.3.3 Modify an Existing Point ... 5-115.6.3.4

Seite 123 - Chapter 7 Get Data Software

5.7.7.3 Record Mode Alarm Output ...5-355.7.8 Format Di

Seite 125 - 7.3 The Menu

Page 5-1Chapter 5 Programming5.1 IntroductionThis chapter provides information for programming the Recorder. Custom programming is required to defi

Seite 126 - Figure 7-1 Export Dialog Box

Page 5-2Chapter 5 Programming5.2.1 Invoking Program MenuPress the MENU button to the far right of the button bar at the bottom of the screen. This w

Seite 127 - Scroll Bar

Page 5-3Chapter 5 Programming5.3 Time and DateThe Time and Date menu item sets the Recorder’s internal clock for time and date dependent features su

Seite 128

Chapter 1 General DescriptionIntroduction ...

Seite 129

Page 5-4Chapter 5 Programming5.4.2 Time FormatThis menu item allows the user to program either American or European time format for the display. Th

Seite 130

Page 5-5Chapter 5 Programming5.4.4 Bar AssignThe Bar Assign menu option allows the user to assign specific points to the individual bars in the bar

Seite 131

Page 5-6Chapter 5 ProgrammingLevel”. Use the UP (↑) or DOWN (↓) Arrow Keys to select a Dim Level and press ENTER. The Dim Levelselection will be on

Seite 132

Page 5-7Chapter 5 Programming5.5.2 ScalesScales are used to display and record all or part of the preselected Output Scale. The user can effectively

Seite 133

Page 5-8Chapter 5 Programming5.5.2.3 Scale GridThe scales are shown on top of the chart with the major and minor divisions. The grid printed on the

Seite 134

Page 5-9Chapter 5 Programming5.5.3.3 Trace WidthThe pen trace widths can be changed from 1 to 7 pixels wide. This value changes all pens displayed.

Seite 135

Page 5-10Chapter 5 ProgrammingThe display reads ‘KXÎXXXXXXXXXXXXÍ‘ (only a total of 13 characters will show on display). Press ENTER toaccept the di

Seite 136

Page 5-11Chapter 5 Programming5.6.3 Point OptionsAfter a point number is chosen, if the point is a new point to program, the point can be setup from

Seite 137

Page 5-12Chapter 5 ProgrammingAt any point, if you exit the Points programming menu after having made any changes, (repeatedly pressingexit) you will

Seite 138

Page 5-13Chapter 5 ProgrammingProgramming Input Scale - Use the UP (↑) or DOWN (↓) Arrow Keys to highlight “Input scale”. PressENTER and the display

Seite 140

Page 5-14Chapter 5 Programming5.6.5.6 FilterThe digital filter smooths noisy or erratic signals by attenuating the effects of sudden transitions. Th

Seite 141

Page 5-15Chapter 5 Programming5.6.5.9 Eng UnitA maximum five-character alphanumeric engineering units message may be assigned for voltage andcurrent

Seite 142

Page 5-16Chapter 5 ProgrammingProgramming from “Alarms” prompt - At the “Alarms” prompt in the Point Setup Menu, pressENTER. The display will show a

Seite 143

Page 5-17Chapter 5 Programminge. Abnormal Alarm TypeAn abnormal alarm is a condition that exceeds any of the bounds of normal operation. Thisincludes

Seite 144

Page 5-18Chapter 5 Programming5.6.5.10.3 Alarm Delay An Alarm Delay can be set for each alarm. This delay prevents the alarms from activating until

Seite 145

Page 5-19Chapter 5 ProgrammingProgramming Parameters - Once a point has been selected and defined as Calculated, the CalculationType Programming menu

Seite 146

Page 5-20Chapter 5 ProgrammingSetting Up Start Time - If the Start Time is correct, press ENTER and proceed to Interval. If theStart Time is not cor

Seite 147

Page 5-21Chapter 5 Programmingc.2 Weekly Auto ResetTo reset the point once a week use the Weekly reset option. Use the UP (↑) or DOWN (↓) ArrowKeys t

Seite 148

Page 5-22Chapter 5 ProgrammingProgramming Gate Control - Use the UP (↑) or DOWN (↓) Arrow Keys to highlight “Gate control” andpress ENTER. Use the Y

Seite 149

Page 5-23Chapter 5 Programming5.6.5.19 Set CndtionlThis menu item allows the user to program a set of conditions for a point. Up to 40 operators ca

Seite 150

Chapter 1 General DescriptionPage 1-1CHAPTER 1Figure 1-1 Solid State Data RecorderThis manual is a user reference guide for the Solid State Paperles

Seite 151

Page 5-24Chapter 5 ProgrammingCurrent Inputs Voltage Shunt - Current inputs are converted to voltage by means of an external 50 ohm shuntresistor sup

Seite 152

Page 5-25Chapter 5 Programming5.6.8 Industrial Square Root Current/Voltage Point TypesThe Recorder accepts three voltage square root extraction rang

Seite 153

Page 5-26Chapter 5 ProgrammingProgramming Parameters - Selecting Log Linear point types requires setting up parameters like regularProgramming linear

Seite 154

Page 5-27Chapter 5 Programming5.6.12 Calculated Point TypesThe following menu items are available through the Calculated Point Type menu:EquationHig

Seite 155

Page 5-28Chapter 5 Programming5.6.12.2 Hi PeakCalculated Point Types with a Point Range of Hi Peak keep track of the highest data of a given point.

Seite 156

Page 5-29Chapter 5 Programming5.6.12.5 Moving AverageA Calculated Moving Average point calculates the continuous average of the measured or processe

Seite 157 - (Required for all returned

Page 5-30Chapter 5 Programming5.6.12.8 TotalizeThe totalize calculation keeps a running total of the value of a point sampled at a programmed rate.

Seite 158 - PACKING INSTRUCTIONS

Page 5-31Chapter 5 Programming5.6.14 External Point TypesExternal Point Types use data sent via the Com port to the Recorder for trending or other u

Seite 159

Page 5-32Chapter 5 Programming5.7.3 Record ModeThere are three options “Fill Mode”, “Inst/Avg All” and Inst/Avg Indiv”. The “Fill Mode” determines w

Seite 160 - 1071-4882-116

Page 5-33Chapter 5 Programming5.7.3.2.2 Inst/Avg Indiv.The user has the option to set the Instantaneous or Average mode for each channel individually