Monarch-instrument PLT200 Bedienungsanleitung Seite 6

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 14
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 5
3
4.0PLT200 SPECIFICATIONS
Laser Specifications:
Classification: Class 3R (per IEC 60825-1 Ed 1.2 2001-8)
Complies with FDA performance standards for laser products except
for deviations pursuant to Laser Notice No. 50, dated July 26, 2001.
Maximum Laser Output: 3mW
Pulse Duration: Continuous
Laser Wavelength: 650 nm
Beam Divergence: < 1.5 mrad
Beam Diameter: 4 x 7 mm typical at 2 meters
Laser Diode Life: 8,000 operating hours MTBF (1 year
warranty)
Non-Contact Specifications:
Ranges: RPM 5 – 200,000
RPS 0.084 – 3,333.3
RPH 300-999,990
Resolution: Fixed: 1 (10 above 99,999)
Auto-ranging: 0.001 to 1.0 (10 above 99,999)
Accuracy: ±0.01% of reading or resolution limit
Operating Range: up to 25 feet (7.62 m) or up to 70 degrees off
perpendicular to T-5 tape target
Contact Specifications using optional Remote Contact Assembly:
Range: Contact Tips: 0.5 to 20,000 RPM
10 cm / 12-inch Wheel: 0.5 to 12,000 RPM
Resolution: Fixed: 1 (10 above 99,999)
Auto-ranging: 0.001 to 1.0 (10 above 99,999)
20
8. Save and
advance
9. Exit Setup –
Ready to
measure
Measure:
Reset
Lap
Power Off
Unit will remember these settings (including lock on/off) even if turned off
and back on.
DONE, then Units
selected
Manual
Auto
Each press toggles Start and Stop
Start and Stop triggered by
Remote Optical Sensor (ROS)
With Timer stopped -
Resets time to 00:00.0
With Timer running -
Stops at elapsed time to date.
To continue, press again.
OR
9.2 TIMER Operation
Automatic after 90 seconds
if unit not Locked on
OR
Seitenansicht 5
1 2 3 4 5 6 7 8 9 10 11 12 13 14

Kommentare zu diesen Handbüchern